fIfrelevant,connectakeyboardtotheProcessorUnit.
MakesurethatthekeyboardworksintheSU90userinterface.Openrelevant
functionsordialogboxes,andmakesurethatyoucantypeinthem.
2SelecttheicononthetopbartoopentheMessagesdialogbox.
aVerifythatnoerrormessagesarepresentedduringnormaloperation.
bClosethedialogboxbyselectingCloseor[X]initstoprightcorner.
Result
Requirements
Results
ThebasicfunctionalityoftheSU90ispresent.
Noerrormessagesarepresented.
Dateandsignature:
VerifyingSU90operationbymeansofthe
BITEfunctionality
ThepurposeoftheBITE(Built-InTestEquipment)dialogboxistoallowon-linetesting
andvericationoftheSU90hardwarecomponents.
Prerequisites
TheSU90hasbeensetupwithitshardwareunitsconnectedasspeciedintheSU90
Installationmanual.
TheSU90systemisturnedonandoperatesnormally.
TheSU90isinNormalmode,butTXPowerissettoOfftopreventtransmissions.
Thetransducerisretractedtoitsupperposition.
Thevesselisberthed.
Neithertoolsnorinstrumentsarerequired.
Caution
YoumustneversettheSU90to"ping"unlessthetransducerissubmergedinwater.
Thetransducermaybedamagedifittransmitsinopenair.
Forthebestpossibleconditions,theshipmustbe"silent".
Thewatermustbeasdeepaspossible.
Theremustbenoothervesselsinthevicinity.
Thevesselmustliestillinthewater.