4Makethefollowingpreparations.
aOntheMainmenu:
SetRangeto1500m.
bOpentheOperationmenu.
SetTxPowertoOff.
cOpentheActivemenu.
1SetPulseTypetoCWMedium.
2SetFrequencyto20kHz.
3SetVerticalTXSectortoNarrow.
4SetNoiseFiltertoOff.
5SettheBottomFilterThresholdtoOff.
dOpentheSetupmenu.
SelectBITEtoopentheBITE(Built-InTestEquipment)dialogbox.
5SelectTransceivertoopenthepage.
Thispageprovidesagraphicpresentationofthe12transceiverboards.The
presentationreectstheirphysicallocationintheTransceiverUnit.Only
staticinformationisprovided.TheBoardInformationparametersofferkey
informationaboutthesupplypowertotheselectedtransceiverboard,aswellas
theenvironmentalconditions.
6Makesurethatallthe12transceiverboardsarefullyfunctional.
7SelectTransducertoopenthepage.
TheTransducerpagepresentsalltheelementsthatareusedintheSU90transducer.
Thepresentationattemptstoorganizetheelementsinthesamemannerasinthe
physicaltransducer.Thetransceiverboardsareshownas"buttons".Selecta
transceiverboardtohighlighttheelementsthatarephysicallyconnectedtothe
board.
8SelectReceptionTesttostartanautomatictestoftheindividualtransducerelements.
ThereceptiontestvalidateseachsingleelementintheSU90transducer,andreturns
thestatususingasimplecolourcoding.
Green:Thetransducerelementisfullyoperational.
Red:Thetransducerelementoffersreducedperformance.
Black:Thetransducerelementisnotworking("dead").
Formoreinformation,observethetooltipprovidedforeachelementrectangle.
9Verifythatthemaximumnumberofunserviceable("dead")elementsdoesnot
exceed4.
Asmallnumberofunserviceabletransducerelementsareaccepted,evenfor
operationaluse.Thisisregardedas"gracefuldegradation”.