EasyManuals Logo

Simrad SU90 Harbour Acceptance Test

Simrad SU90
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
409977/B
43
ThepropertiesofeachoftheavailablecommunicationportsaredenedontheI/OSetup
page.TheSensorInstallationpageallowsyourSU90tocommunicatewithexternal
sensorsandsystems.Tomakesurethattheinformationfromthe"mostreliable"sensors
areusedbytheSU90,usetheSensorCongurationpagetodeneadatagrampriorities.
ThecommunicationparametersdenedforNMEA0183are:
BaudRate:4800bit/s
DataBits:8
Parity:None
StopBits:1
Procedure
1OpentheSetupmenu.
2OntheSetupmenu,selectInstallation.
ObservethattheInstallationdialogboxopens.Thisdialogboxcontainsanumber
ofpagesselectedfromthemenuontheleftside.
3OntheleftsideoftheInstallationdialogbox,selectSensorInstallation.
aSelecttherelevantsensorintheInstalledSensorslist.
bMakesurethatthecorrectinstallationparametersareusedforthesensor.
4OntheleftsideoftheInstallationdialogbox,selectSensorConguration.
aSelecttherelevantsensorintheSensorlist.
bMakesurethatthecorrectparametersareusedforsensorconguration.
5ClosetheInstallationdialogboxwithoutmakinganychanges.
6Observethetopbar.
7Makesurethattheinformationfromthesensorisdisplayed.
Ifnecessary,enabletheread-outintheDisplayOptionsdialogbox.
8Ifpossible,useanotherinstrumenttoverifythattheinformationprovidedbythe
SU90iscorrect.
9Fillintheresulttables.
Result
DatagramPortBaudrateTalkerID
Testingtheinterfaceswithperipheraldevices

Table of Contents