Page #21 background imageLoading...
Page #21 background image
INTEGRATION WITH SKF @PTITUDE OBSERVER
Hierarchy view adding sensors and measurements
SKF Enlight Collect IMx-1 System
User Manual
Revision A
21 (84)
Figure 7 IMx-1 Engineering unit selection
Engineering units for each of the four measurement types can be chosen and the
following alternatives are available:
Acceleration: g or m/s^2
Velocity: mm/s or ips
Envelope: gE or m/s^2E
Temperature: C or F
As shown, the scaling/detection method applicable to the vibration measurements, is
fixed. The temperature unit selection also governs the units used for the gateway,
internal temperature measurement.
2.2 Hierarchy view adding sensors and measurements
IMx-1 sensors are added to sub-machines in the @ptitude Observer Hierarchy. Right
click on the appropriate asset node and select "Enlight Collect IMx-1 Sensor" from
the "Add" sub-menu:
Figure 8 Add IMx-1 Sensor
When added to the hierarchy a node for the IMx-1 sensor is created along with a four
point ‘cluster’ of Temperature, Acceleration, Velocity and Envelope measurements,
refer the figure below.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF Enlight Collect IMx-1 and is the answer not in the manual?

SKF Enlight Collect IMx-1 Specifications

General IconGeneral
BrandSKF
ModelEnlight Collect IMx-1
CategoryAccessories
LanguageEnglish

Related product manuals