Installation DL2 Doppler Speed Log System
seTup aux
The Auxiliary inputs and outputs can be assigned to different functions in the AUX Setup screen.
If Speed warning is selected on one of the output channels, then the user can set a high and low
limit. At this speed the state of the output will change.
The current state of the AUX input and outputs are shown in the table below
Name Type Pin numbers (J2 Aux)
Aux 1 Output Opto-isolator 7 +, 9 -
Aux 2 Output Opto-isolator 2+, 4-
Aux 3 Relay Relay 1 NC, 3 Com, 5, NO
Aux 1 Input Opto-isolator 2+, 4-
Speed warning changes the output state as the vessels speed passes a set speed, this can have 2
values low and high. These values are set using below buttons.
NOTE. Do not use the Aux 3 Relay output for pulse speed output as the relay has a limited number
of switching cycles.
Options for the Auxilliary output are.
Option Description Option Code
required?
STWPulseOutput 200 PPNM showing STW No
SOGPulseOutput 200 PPNM showing STW No
AlarmBeepOutput The output will click 3 times every 7 seconds when
an unacknowledged alarm is active
No
AlarmOutput The state will change when an unacknowledged alarm
is active
No
SpeedLimit The State will change when it enters the speed zone No
AlarmReset (input) All active alarms will be acknowledged when the
state of this is changed
No
Mute (input) The sensor is silenced when this is active Sync Option
Synch Out When the sensor is conrmed silenced, this changes Sync Option