The following items are not SKIPPER supplied:
- LAN cable (minimum CAT6) from Operator unit to Electronic unit.
- The sensor is manufactured with a 40m cable. The cable may be cut or extended. Extension cable
is minimum CAT7 type. See chapter 3 for lengths and dimensions.
The following power supplies are required
- CU-M001-SA. Operator Unit. 24VDC. Max 10W, Typical 6W.
- JB70D2-SA. Electronic unit: 24VDC and/or 115/230VAC. Max 60W typical 15W.
There are no power switch on the CU-M001-SA or JB70D2-SA.
The power input should be including a manual circuit breaker.
There are no input fuse on the CU-M001-SA or JB70D2-SA.
The power input should be including a fuse rated for 100% - 200% of max power installed components.
Example: 24V DC to power CU-M001-SA and JB70D2-SA should have a 3A slow blow fuse.
Optional items power supply requirement:
- CD401MR repeater. 24VDC. Max 10W, Typical 6W.
- IR31DIM-SA. External dimmer: 24VDC
- LAN switch: 24VDC