Section 5 – Operation Operate with the emergency power switch at the platform control console
5.21 Operate with the
emergency power switch
at the platform control
console
This switch enables all of the functions, with the
exception of drive, if there is an engine malfunction.
Refer to Section 6.1 for the emergency-lowering
procedure.
5.22 Engage or disengage the
differential lock switch
1. Move the differential lock switch forward and
release it to lock or unlock the differential.
5.23 EcoStart
1. The EcoStart functionality ONLY shuts down the
engine under all of these specic conditions:
The engine coolant temperature is more
than 70 degrees Celsius
The generator switch is turned off.
No engine powered function from the
platform has been used for more than 3
minutes.
2. If EcoStart functionality shuts down the engine
the light illuminates. If required to use the engine
power, select the start position from the start/
function enable/emergency power switch until
the engine starts.
5.24 MEWP shutdown
1. Select a reasonably well-protected location to
park the MEWP. This location must have a rm,
level surface, clear of obstructions, and trafc.
2. Fully retract the boom and lower the platform.
3. Push the emergency-stop button on the
platform control console.
4. Exit the platform.
5. Turn the base/off/platform key switch to the off
position and remove the key.
6. Push the emergency-stop button on the base
control console.
7. Turn the main power disconnect switch to the
off position.
8. If it is necessary, put a cover on the platform
control console to prevent damage to
the warning labels and controls in hostile
environments.
5.25 Generator (optional
equipment)
To start the generator:
1. Make sure the engine is on.
2. Turn the generator on/off switch to the on
position.
To restore normal operation:
3. Turn the generator on/off switch to the off
position.
5.26 Glazier Tray (optional
equipment)
The glazier tray attaches to the kickplate of the
platform. Refer to the glazier operation manual for the
correct operation and maintenance.
5.27 Pipe Rack (optional
equipment)
The pipe rack attaches to the kickplate of the platform.
Refer to the glazier operation manual for the correct
operation and maintenance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ46 AJ and is the answer not in the manual?

Skyjack SJ46 AJ Specifications

General IconGeneral
BrandSkyjack
ModelSJ46 AJ
CategoryLifting Systems
LanguageEnglish

Related product manuals