IDP 600 Terminal Series - Hardware Guide
© SkyWave Proprietary 13 T200, Version 02
3.3.1 Digital Input
Figure 12 shows a schematic of the I/O when configured as a digital input.
Figure 12 Digital Input
The input specifications are provided in the table below.
Input current with weak pull-down
(weak 1 MΩ pull-down still in place);
V
in
= 3.0 V
Input source current with pull-up
(V
in
= 0.0 V)
Input sink current with pull-down
(V
in
= 3 to 150 V)
INPUT
DIGITAL
1k
3V
ARM PROCESSOR
1M
3V
1nF
1k
3V
LIMITER
3V
S1
40k
S2
40k