11 Device Administration
SMA Solar Technology AG
Operating manualHM-20-BE-en-1964
Figure 12: System extension with radio-controlled socket (example)
Detailed information on the configuration of new loads can be found under Load overview and planning (see
Section12.2, page73).
FRITZ!DECT radio-controlled sockets automatically measure the ambient temperature near the device. The
temperature is displayed on the menu page Smart Home > Temperature.
11.5.2 Adding Modbus Device
Requirements:
The new device must have been installed in the system and commissioned in accordance with the manufacturer
specifications.
The Modbus configuration must have been performed on the SunnyHomeManager (see Section11.3.13,
page61).
For the SunnyHomeManager this must be set: Data request interval Automatic (see Section11.3.9,
page59).
Procedure:
1. Under Configuration > Device overview select the tab Overview of new devices.
2. Select device after preselection via the device filter or in the list and activate via .
The configuration wizard opens and provides the further procedure step by step.
3. Enter the device name. You can also select and edit one of the suggestions displayed.
4. Click on [Next].
5. In the drop-down list select the Load that is connected to the Modbus device.
If the required load is not available, select No assignment and then add the new load later.
6. Click on [Next].
A summary of your entries is displayed.
7. If the data are correct, click on [Finish].
You are automatically forwarded to the tab New load of the configuration page Load overview and
planning to configure the new load.
Currently only 1 load can be switched per 1 Modbus device.