13 Visualization of the energy management
SMA Solar Technology AG
Operating manualHM-20-BE-en-1992
Position Explanation
B Suitable time for manually switching on loads
The SunnyHomeManager takes the following information into consideration for the recommended
action:
• Expected PV power (see position C)
Requirement: The location of the system must be set.
• Expected energy consumption of the household and of loads for which the
SunnyHomeManager receives measured values of the power consumed via switching device
or via direct communication. The SunnyHomeManager determines the anticipated energy
consumption in accordance with the consumption forecast based on the "learned"
consumption behavior of the individual household.
Requirement: The data collection of the loads must be activated.
• Feed-in tariff and electricity tariff
Requirement: The feed-in tariff and electricity tariff must be entered.
• Optimization target
The optimization target indicates whether the Sunny Home Manager should prioritize
ecological- or economical factors during load management.
• Azimuth and tilt angle
Requirement: The inverter strings must be configured.
C Expected PV power in accordance with the PV yield forecast
The SunnyHomeManager determines the available PV power that can be expected in each case
using the weather forecast for the selected location and the "learned" behavior of the specific sys-
tem.
Tip: When you move the mouse over one of the bars, the following details for this time period will
be displayed in a window:
• Estimated PV generation
• Estimated consumption
• Difference between the estimated PV generation and estimated consumption
D Tariff for the electric current purchased from the utility grid
• Red: expensive
• Green: good value
If you have only entered 1 electricity tariff, green is always displayed.
• Other colors: electricity tariffs between the highest and the lowest electricity tariff
E View of the time periods for the planned operation of the loads (load prognosis)
• The configured time periods are shown as colored, semi-transparent bars.
• Time periods planned by the SunnyHomeManager in which the loads were actually in
operation or are going to be in operation are shown as colored, solid bars.
A simple solid line symbolizes times during which the self-consumption of the load is measured.
F Loads legend
The legend shows which color is assigned to which load in the time period view (E).
13.4 Energy Balance
This page visualizes the progression of the energy generation and energy consumption for a selected period. provides
analyses for generation, consumption, self-consumption and battery usage.