SMA Technologie AG Archiving Data on an MMC/SD Card
Technical Description SI5048-11:EE4206 Page 79
11.2 Inserting the Card
11.3 Removing the Card
11.4 Saving and Loading Parameters
Using the "#410.02 ParaSto" parameter, you can save the current parameter settings
and using the "#410.08 ParaLod" parameter, you can load the saved parameters.
You have the following selection options when saving the parameters:
Set1 (save parameter set 1)
Set2 (save parameter set 2)
You have the following selection options when loading the parameters:
Set1 (load parameter set 1)
Set2 (load parameter set 2)
Factory (load the factory settings (reset))
After inserting the MMC/SD card into the Sunny Island
5048, a message appears on the display prohibiting the
removal of the card:
The initialization of the MMC/SD card can take several
minutes. During this time, the keys are disabled and cannot
be used for making entries. Three points appear in the lower
line of the display.
If the operation was successful, the following is shown on the
display:
In case of a fault, the following appears:
In order to ensure that all log data is saved when switching off the device, stop
the Sunny Island 5048 (see section 9.2 "Stopping" (Page 62)) and then switch it
off using the DC circuit breaker (9.3 "Deactivation" (Page 63)). You can also
write all unsaved data from the buffer on the MMC/SD card using the "#440.01
CardFunc" parameter and by selecting the "Flush" option.
Once the system is working optimally, it is a good idea to save these settings. This
is especially useful if you try something new and then later wish to reset the inverter
back to the previous settings.
Do not remove
MMC/SD card ...
MMC operatin
finished
MMC operatin
failed