SMA Solar Technology AG 4 Product Description
Installation Manual SI80H-60H-OffGrid-IA-en-11 23
E Grid LED Off No voltage is present at the
connection of the external energy
source.
Glowing
green
External energy source is connected.
Glowing
orange
The off-grid inverter is synchronising
the stand-alone grid to the external
energy source.
Glowing red Error at the external energy source
connection.
F Battery LED Glowing
green
The battery charge level is over 50%.
Glowing
orange
The battery charge level is between
50% and 20%.
Glowing red The battery charge level is below
20%.
G AC operation ‒ Symbol indicates the area for starting
and stopping inverter operation.
H Standby ‒ Symbol indicates the area for
switching the inverter on and off.
* flashing at intervals of 0.5 s – 1 s
** flashing at intervals of 1.5 s – 2 s
Position Symbol Description Status Explanation