7. Attach the off-grid inverter to the wall mounting
bracket on both sides using M6x10 screws and an
Allen key (AF 5) (torque: 4 Nm ... 5.7 Nm).
The off-grid inverter is thus prevented from being
lifted off.
8. Cover the recessed grips with the ventilation grids:
Place the ventilation grid marked links/left on
the left recessed grip.
Place the ventilation grid marked rechts/right
on the right recessed grip.
9. In order to protect the off-grid inverter against theft,
attach the off-grid inverter to the wall at the bottom
using two safety screws.
10. Ensure that the off-grid inverter is firmly in position.
6.
Risk of injury due to the heavy weight of the off-grid inverter
Take into account the weight of the off-grid inverter (see Section 12"Technical
Data",page144).
Hook the off-grid inverter onto the wall
mounting bracket.
Use the side recess grips or a steel rod to
help you (diameter: maximum 30 mm). Keep
the off-grid inverter horizontal when moving
it.