series - Use and maintenance manual
17
Translation from the original
2.7 ELECTRICAL CONNECTION
Power must be cut from the machine for all operations involving connection to the electrical
network.
ATTENTION!
Whenever accessing the electrical system, remember to cut the power and to wait at
least five minutes before operating.
THE EARTH CONNECTION IS COMPULSORY!
Connecting the machine to the mains must be carried out in compliance with standards in force
in the user's country.
Check to make sure that the machine's power supply frequency and voltage (see plate
applied on the machine) correspond to the power supply network.
2.8 ELECTRICAL INSTALLATION DATA
Install a circuit breaker on the machine power supply line which supports the values indicated
in the table.
2.9 CONDITIONS FOR USE
The machines must operate exclusively indoors, protected from the elements, where there are
no explosive atmospheres.
Make sure there is room for its easy installation and maintenance.
The minimum lighting must be 300 lux.
Operating temperatures ranging from +10°C to +40°C are recommended, with a relative
humidity from 30% to 80% without condensation.
Machine protection grade = IP20
SL45 SL55
Nominal
voltage
220÷240 V
(1PH+N+PE)
220÷240 V
(1PH+N+PE)
Nominal
frequency
50÷60 Hz 50÷60 Hz
Nominal
power
1650 W 3700 W
Nominal
current
7 A 17 A