PROBLEM CAUSE SOLUTION
ERROR 4
The heat shrinking
temperature increases in
sealing mode.
Disconnect the power cable and perform
the following controls:
-check the proper connection of the
heating elements to the circuit board;
-check functioning of the circuit court
Attention - at times the error can be
displayed while passing from the heat
shrinking mode to the sealing mode.
If the problem continues, interrupt sealing
or heat shrinking operations, disconnect
the power cable and contact the
assistance centrer.
ERROR 5
PCB temperature too high.
Disconnect the power cable and perform
the following controls:
-check whether the air vents are
obstructed;
-make sure the cooling fan of the circuit
board works properly.
If the problem continues, interrupt sealing
or heat shrinking operations, disconnect
the power cable and contact the
assistance centrer.
ERROR 6
The NTC cooling flap
temperature is too high.
Disconnect the power cable and perform
the following controls:
-check whether the air vents are
obstructed;
-make sure the cooling fan of the circuit
board works properly.
If the problem continues, interrupt sealing
or heat shrinking operations, disconnect
the power cable and contact the
assistance centrer.
ERROR 7
The NTC temperature is not
standard.
-Make sure the cooling fan works.
-make sure the room temperature
< 40° C.
If the problem continues, disconnect the
power cable and contact the assistance
center.
ERROR 8
Calibration parameters error.
An error has been triggered in
the stored data.
Turn the machine off and back on again.
If the problem continues, disconnect the
power cable and contact the assistance
centre.
ERROR 9
EEPROM error.
A fault has occurred in data
storage
Press “+” and then reset the correct
machine model.
If the problem continues, disconnect the
power cable and contact the assistance
centre.