Use and maintenance manual
T450 - T650E - T650EF - T650 - T650F
ENGLISH
EARTHENING IS COMPULSORY!
The connection of the tunnel to the mains must be performed in compliance with the
regulation s in force in the country of the user.
Check that the tunnel frequency and supply voltage values (see data plate on the rear
side of the tunnel) correspond to the main's value.
ATTENTION!
IF THE ELECTRONIC CARD HAS TO BE EXTRACTED, REMEMBER TO REMOVE
THE VOLTAGE AND TO WAIT AT LEAST 5 MINUTES BEFORE OPERATING.
2.11 TECHNICAL DATA FOR THE ELECTRIC CONNECTION
2.12 CONDITIONS OF USE
THE MACHINE NEEDS AN INSTALLATION IN A CLOSED AND WELL AIRED
SURROUNDING,WHERE THERE ARE NOT ANY EXPLOSION OR FIRE
DANGEROUS. THE MINIMUM LIGHTING MUST BE 300 LUX.
Make sure that there is enough space for easy application and maintenance. Position
the machine in the planned space with no humidity, flammable materials, gas, and
explosives and making sure that it is level on the floor.
We suggest operating temperatures varying from +10°C to +40°C with a relative
humidity from 30% to 80% with no condensation.
The airborne noise is lower than 70 dB.
MACHINE PROTECTION DEGREE = IP32
Tab. 2.11.1
T450
T450
THREEPHASE
T650 T650EF
T650EF
THREEPHASE
T650F
RATED
VOLTAGE
380-415 V ~ 220-240 V ~ 380-415 V ~ 380-415 V ~ 220-240 V ~ 380-415 V ~
RATED
FREQUENCY
50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz
RATED
POWER
7950 W 7950 W 15900 W 13850 W 13850 W 21300 W
RATED
CURRENT
11.5 A 21 A 23 A 23 A 40A 30.5 A
+40°C
+10°C