PROBLEM 11: Lack of one phase on power supply:
Solution:
Make sure that all the three phases come from the mains.
Check the cables connection; connect them again, if necessary.
PROBLEM 101:Wrong temperature sensor:
Solution:
Turn off the power supply.
Make sure that the earth connections are correct (those of the supply mains too);
Make sure that the sensor's connection terminals are well shut.
If the problem continues replace the board.
PROBLEM 102:Temperature sensor at maximum value:
Solution:
Turn off the power supply.
Make sure that the earth connections are correct (those of the supply mains too);
Make sure that the sensor's connection terminals are well shut.
If the problem continues replace the board.
PROBLEM 103:Temperature reading sensor unstable:
Solution:
Turn off the power supply.
Make sure that the earth connections are correct (those of the supply mains too);
Make sure that the sensor's connection terminals are well shut.
If the problem continues replace the board.
PROBLEM 104:Temperature regulation zone out of the rated range of regulation:
Solution:
Check if the heating resistors are operating correctly.
Check that there is no voltage on the resistors in the free passage mode, the
possible presence of voltage on some resistors indicates that the static relays are
broken.
Check that the card operates correctly at a lower temperature: if the operation is
regular the problem is put down to a wrong regulation.
If the problem continues replace the card.
PROBLEM 105:Temperature of more than 20°C, as compared to the preset value:
Solution:
Set the oven properly:
Check if the heating resistors are operating correctly.
Check that there is no voltage on the resistors in the free passage mode, the
possible presence of voltage on some resistors indicates that the static relays are
broken.
Check that the card operates correctly at a lower temperature: if the operation is

Table of Contents