16
Fig. 9 CT / RS485 / NTC connection
Step 3: Loosen 4 screws (part A) using a screwdriver (fig. 9)
Step 4: Remove the waterproof cover (part B), loosen the cable gland (part C), then remove the stopper (part G)
Step 5: Route CT cable through the cable gland, connect CT cable to CT terminal, then insert CT terminal into
corresponding ports.
Step 6: one communication cable is provided in the ME3000SP accessory bag. One inverter end, one BAT end.
Route the communication cable (inverter end) through the cable gland, insert the 4P4C connector to ME3000SP CAN
port. Insert the 8P8C connector (BAT end) to PYLONTECH battery CAN port.
Communication cable between battery & ME3000SP
CAN communication
ME3000SP
CAN port
PYLONTECH US2000 PLUS / US2000B
CAN port
Note: Please confirm with representative of PYLONTECH
that your battery is compatible with ME3000SP