6.3 Commissioning
The main interface:
Fig 15. Screen of ME3000SP
If you didnt change the work mode of ME3000SP, which means ME3000SP is working in Auto Mode”:
WhilePV Production> Home Consumption(fig 15)
If the battery is not full. ME3000SP will charge the battery.
WhilePV Production< Home Consumption(fig 15)
If the battery is not flat. ME3000SP will discharge the battery.
Every time you change the CT connection, you need to restart ME3000SP. Please follow the following procedure:
1. Turn OFF PV inverter. Turn ON some home appliances.
2. Turn OFF AC circuit breaker (grid) / DC isolator (battery). Wait 5 minutes.
3. Turn ON DC isolator (battery), then turn ON AC circuit breaker (grid). Wait 1 minute.
4. Turn ON PV inverter.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sofar ME3000SP and is the answer not in the manual?

Sofar ME3000SP Specifications

General IconGeneral
ModelME3000SP
ManufacturerSofar Solar
TypeHybrid Inverter
Rated Power3000 W
Max PV Input Voltage500 V
Max PV Input Current13 A
Battery Voltage Range40-60 V
Efficiency97.5%
Max. DC Voltage500 V
Number of MPPTs1
Max. Input Current per MPPT13 A
Max. AC Power3000 W
Max. AC Current13.6 A
Rated AC Voltage230 V
AC Voltage Range180-280V
Rated Frequency50/60 Hz
THDi<3%
Euro Efficiency97%
DC SwitchYes
Protection DegreeIP65
Operating Temperature Range-25°C to +60°C
CoolingNatural Convection
CommunicationRS485, WiFi (optional)