9)*Set max discharge current (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the max discharge
current per your battery specification, press “Ok”, then “Set min protect voltage” will pop up.
10)*Set min protect voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the min protect voltage
per your battery specification, press “Ok”, then “Set discharge depth” will pop up.
11)*Set discharge depth (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the discharge depth
per your battery specification, press “Ok”, then “Set empty discharge voltage” will pop up.
12)*Set empty discharge voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the empty discharge
voltage per your battery specification, press “Ok”, then “Set full charge voltage” will pop up.
13)*Set full charge voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the full charge voltage
per your battery specification, press “Ok”.
Congratulations, ME3000SP’s first time setup is complete. Please press “OK” to enter the main interface.
5) Turn ON some home appliances.
6) Make sure the electricity consumption in ME3000SP’s phase is greater than 200W.
“Grid import power” shall equal “Home Consumption” now. (fig 15)
7) Turn ON PV inverter. “PV Production” shown on ME3000SP shall equal total power
generation in ME3000SP’s phase now. (fig 15)