23
MENU Compatible Batteries
1.PYLON PYLONTECH US2000 PLUS / US2000B
Note: Please confirm with representative of PYLONTECH that your battery
is compatible with ME3000SP
2. DARFON DARFON 14S31P ESS
3.DEFAULT LEAD ACID / LEAD CRYSTAL / AQUION battery
4. General Lithium All batteries that comply with SOFAR’S BMS CAN communication protocol.
5. Alpha. ESS M48112-P / SMILE-BAT
6. SOLTARO SL-3KWH / SL-1KWH
4)*Set battery capacity (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the battery capacity
per your battery specification, press “Ok”, then “Set max charge voltage” will pop up.
5)*Set max charge voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing max charge voltage
per your battery specification, press “Ok”, then “Set max charge current” will pop up.
6)*Set max Charge current (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the max charge current
per your battery specification, press “Ok”, then “Set max protect voltage” will pop up.
7)*Set max protect voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the max protect voltage
per your battery specification, press “Ok”, then “Set min discharge voltage” will pop up.
8)*Set min discharge voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the min discharge
voltage per your battery specification, press “Ok”, then “Set max discharge current” will pop up.