To allow for heat dissipation, maintain clearance as specified below.
Figure 3: Power optimizer clearance
When installing modules in a confined space, for example, if installing Building-
integrated photovoltaic (BIPV) modules, ventilation measures may be needed to
ensure the power optimizers are not be exposed to temperatures outside their
specifications.
Step 1: Mounting the Power Optimizers
For each of the power optimizers
(1)
:
1. Determine the power optimizer mounting location and use the power
optimizer mounting brackets to attach the power optimizer to the
support structure . It is recommended to mount the power optimizer
in a location protected from direct sunlight. For frame-mounted
power optimizers follow the instructions supplied with the optimizers,
or refer to https://www.solaredge.com/sites/default/files/installing_frame_
mounted_power_optimizers.pdf.
2.
If required, mark the mounting hole locations and drill the hole.
CAUTION!
Drilling vibrations may damage the power optimizer and will void the
warranty. Use a torque wrench or an electric drill with adjustable clutch that
meets the mounting torque requirements.
Do not
use impact drivers for
mounting the power optimizer.
Do not
drill through the power optimizer or through the mounting holes.
(1)
Not applicable to smart modules.
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5
18 Step 1: Mounting the Power Optimizers

Table of Contents

Other manuals for SolarEdge SE5000H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5000H and is the answer not in the manual?

SolarEdge SE5000H Specifications

General IconGeneral
ModelSE5000H
ManufacturerSolarEdge
TopologyTransformerless
AC Nominal Power5000 W
Rated AC Power5000 W
CoolingNatural Convection
Noise Level< 25 dBA
Protection RatingIP65
Max. Input DC Voltage480 Vdc
Number of MPP Trackers1
AC Voltage240 V
Weight10.6 kg
Operating Temperature Range-25°C to 60°C