Appendix A: Errors and Troubleshooting
This chapter describes general system problems, and how to troubleshoot them. For
further assistance, contact SolarEdge Support.
Identifying Errors
Errors may be indicated in various system interfaces: On the inverter bottom panel, a
red LEDindicates an error, see the following figure. In the monitoring platform and
SetApp, errors are displayed with codes.
For more information on the codes displayed for error and warning
messages, refer to http://www.solaredge.com/sites/default/files/se-
inverter-installation-guide-error-codes.pdf. This document describes
errors that appear in SetApp, monitoring platform, and LCD (for inverters
with LCD). To identify the error types, use the methods described below.
To identify the error type using the inverter LEDs:
1. Move the ON/OFF/P switch to P position for 2 seconds and release it.
2.
Observe the LED lights and use the following table to identity the
error type. For more information, refer to
https://www.solaredge.com/leds.
Error type
LEDcolor and state
Red Green Blue
Arc detected ON OFF OFF
Isolation or RCD problem Blinking OFF OFF
Appendix A: Errors and Troubleshooting 61