EasyManuals Logo

SolarEdge SE5000H User Manual

SolarEdge SE5000H
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Power Optimizer
The power optimizers are DC-DC converters connected to PV modules in order to
maximize power harvesting by performing independent Maximum Power Point
Tracking (MPPT) at the module level.
The power optimizers regulate the string voltage at a constant level, regardless of string
length and environmental conditions.
The power optimizers include a safety voltage function that automatically reduces the
output of each power optimizer to 1 Vdc in the following cases:
During fault conditions
The power optimizers are disconnected from the inverter
The inverter ON/OFF/P switch is turned OFF
The inverter AC breaker is turned OFF
Each power optimizer also transmits module performance data over the DC power line
to the inverter.
Two types of power optimizers are available:
Panel Module Add-on power optimizer – connected to one or more modules
Smart modules - the power optimizer is embedded into a module
Monitoring Platform
The monitoring platform enables monitoring the technical and financial performance of
one or more SolarEdge sites. It provides past and present information on the system
performance both at the system and module levels.
EV Charging Single Phase Inverter
The EV Charging Single Phase Inverter (referred to as “inverter”throughout) efficiently
converts DC power from the modules into AC power that can be fed into the main
ACservice of the site and from there to the grid. The inverter also receives the
monitoring data from each power optimizer and transmits it to a central server (the
monitoring platform; requires Internet connection).
The EV Charging Single Phase Inverter is designed to provide reliable and economical
charging of an electric vehicle (EV). It provides Mode 3 EV charging from both the grid
and the PV system, and is designed to work with all plug-in vehicles with J1772 (Type 1)
socket and (Type 2) IEC62196 sockets.
An EV Charger cable (ordered separately)is required for EV charging:
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5
10 Power Optimizer

Table of Contents

Other manuals for SolarEdge SE5000H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5000H and is the answer not in the manual?

SolarEdge SE5000H Specifications

General IconGeneral
ModelSE5000H
ManufacturerSolarEdge
TopologyTransformerless
AC Nominal Power5000 W
Rated AC Power5000 W
CoolingNatural Convection
Noise Level< 25 dBA
Protection RatingIP65
Max. Input DC Voltage480 Vdc
Number of MPP Trackers1
AC Voltage240 V
Weight10.6 kg
Operating Temperature Range-25°C to 60°C