Chapter 4: Connecting the AC and the Strings
to the Connection Unit
This chapter describes how to:
Connect the Connection Unit to the AC grid, and to the PV strings.
If required connect additional grounding, for example for installations in locations
requiring earth rod.
Figure 13: Inside the Connection Unit
To connect the AC grid and grounding to the Connection Unit:
1. Turn OFF the AC circuit breaker.
2.
Open the Connection Unit cover: Release the four Allen screws and carefully move
the cover horizontally before lowering it.
CAUTION!
When removing the cover, make sure not to damage internal components.
SolarEdge will not be held responsible for any components damaged as a
result of incautious cover removal.
3.
Strip the required length of the external and internal cables insulation.
Figure 14: Insulation stripping – AC
4.
Open the AC cable gland and insert the cable through the ACgland.
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5
30 Chapter 4: Connecting the AC and the Strings to the Connection Unit

Table of Contents

Other manuals for SolarEdge SE5000H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5000H and is the answer not in the manual?

SolarEdge SE5000H Specifications

General IconGeneral
ModelSE5000H
ManufacturerSolarEdge
TopologyTransformerless
AC Nominal Power5000 W
Rated AC Power5000 W
CoolingNatural Convection
Noise Level< 25 dBA
Protection RatingIP65
Max. Input DC Voltage480 Vdc
Number of MPP Trackers1
AC Voltage240 V
Weight10.6 kg
Operating Temperature Range-25°C to 60°C