Creating an Ethernet (LAN) Connection
This communication option enables using an Ethernet connection to connect the
inverter to the monitoring platform through a LAN.
Figure 20: Example of Ethernet connection
Ethernet cable specifications:
Cable type – a shielded Ethernet cable (Cat5/5E STP) may be used
Maximum distance between the inverter and the router – 100 m/ 330 ft.
NOTE
If using a cable longer than 10 m / 33 ft in areas where there is
a risk of induced voltage surges by lightning, it is recommend
to use external surge protection devices.
For details refer to:
http://www.solaredge.com/files/pdfs/lightning_surge_
protection.pdf.
To connect the Ethernet cable:
1. Remove the inverter cover as described in
Removing the Inverter Cover
on page 53.
2. Open the communication gland.
CAUTION!
The gland includes a rubber waterproof fitting, which should be used to
ensure proper sealing.
3. Remove the plastic seal from one of the large openings.
4. Remove the rubber fitting from the gland and insert the CAT5/6 cable through the
gland and through the gland opening in the inverter.
5.
Push the cable into the cut opening of the rubber fitting.
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5
54 Creating an Ethernet (LAN) Connection

Table of Contents

Other manuals for SolarEdge SE5000H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5000H and is the answer not in the manual?

SolarEdge SE5000H Specifications

General IconGeneral
ModelSE5000H
ManufacturerSolarEdge
TopologyTransformerless
AC Nominal Power5000 W
Rated AC Power5000 W
CoolingNatural Convection
Noise Level< 25 dBA
Protection RatingIP65
Max. Input DC Voltage480 Vdc
Number of MPP Trackers1
AC Voltage240 V
Weight10.6 kg
Operating Temperature Range-25°C to 60°C