Appendix C: Connecting the Energy Meter To
the Inverter
This section provides instructions for connecting an Energy meter to the EV Charging
Single Phase Inverter.
For Smart Energy Management applications, such as maximizing self-consumption, the
EV Charging Single Phase Inverter requires an Energy Meter.
To install the Energy Meter, refer to the installation guide supplied with it:
Energy Meter DIPSwitches
Energy Meter ID DIPSwitches
The IDDIPswitches are used to set the Modbus address of the meter. The
addressing options are listed in the table below. See the figure
ID and termination DIP
switches
on page 78 for switch direction guidelines.
Table 1: Energy Meter ID DIP Switches
Modbus Address ID 1 ID 2 ID 3
0 Down Down Down
1 Up Down Down
2 Down Up Down
3 Up Up Down
4 Down Down Up
5 Up Down Up
6 Down Up Up
7 Up Up Up
Energy Meter Termination DIPSwitches
The Termination DIPswitches are used to configure RS485 wiring termination. The
termination options are listed in the table below. See the figure
ID and termination DIP
switches
on page 78 for switch direction guidelines and refer to
Table 1
.
Table 2: Energy Meter ID DIP Switches
RS485 Termination TERM 1 TERM 2
Terminated Down Down
Not Terminated (factory default) Up Up
Appendix C: Connecting the Energy Meter To the Inverter 77
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5

Table of Contents

Other manuals for SolarEdge SE5000H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5000H and is the answer not in the manual?

SolarEdge SE5000H Specifications

General IconGeneral
ModelSE5000H
ManufacturerSolarEdge
TopologyTransformerless
AC Nominal Power5000 W
Rated AC Power5000 W
CoolingNatural Convection
Noise Level< 25 dBA
Protection RatingIP65
Max. Input DC Voltage480 Vdc
Number of MPP Trackers1
AC Voltage240 V
Weight10.6 kg
Operating Temperature Range-25°C to 60°C