4 Installation
4 1 Checking the Outer Packing.
a When receiving the inverter check that the packing materials are intact. , .
. , , ,b After unpacking check that the deliverables are complete intact and consistent with your
order list.
c Examine the PV inverter and its fittings for damage such as scraps and cracks. .
Do not install the inverter on flammable building materials or in an
area that stores flammable or explosive materials.
Do not install the inverter in a place where personnel are likely to
come into contact with its enclosure and heat sinks to avoid electrical
shock/burn.
Figure 4 1 The deliverables: The inverter and its fittings.
The deliverables in the fittings of inverter
CAUTION
DANGER
AC output connector
The inverter
Items Deliverables
File package
Rear panel
A
F
G
E
D
C
B
Bolt group (including screw, nut)*3
(reserved for tighteningthe support and rear panel)
M6 screw
DC terminal connector group
G
Removal tool for DC connectors
RS485 terminal block
RS485 connector
H
I J
H
I
J

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X3 Series and is the answer not in the manual?

SolaX Power X3 Series Specifications

General IconGeneral
IP RatingIP65
Frequency50Hz / 60Hz
MPPT Efficiency99.9%
CommunicationWiFi / GPRS / Ethernet
Operating Temperature Range-25°C to +60°C (derating above 45°C)
Number of MPPTs2
AC Output Voltage230V
MPPT Range125V-550V