3g.3.4 IC6004 Checking Procedure
3g.3.4 IC6004 3.3V DDC Checking Procedure
Check EN signal
R6100 voltage
Is voltage > 2.5V?
Change IC6004
Change F6002
no
no
START
yes
Other Causes
Check continuity test
at fuse terminals.
F6002 Shorted?
Check input
F6002 voltage
Is voltage > 19.0V?
Check LK-Board
no
yes
yes