HCD-SHAKE10/SHAKE30/HCDSHAKEX10/HCDSHAKEX30/HCDSHAKEX70
13
2-4. 4CH DAMP BOARD (HCDSHAKEX70)
Ver. 1.1
qg four screws
(+BVTP 3 u 8)
qg one screw
(+BVTP 3 u 8)
5 two screws
(+BVTP 3 u 8)
6 two screws
(+BVTP 3 u 8)
3 cushion
(QJ, S)
7 bracket, fan
(black)
8 DC fan
qk 4CH DAMP
board
qj bracket,
heat sink
qh
qa two screws
(+BVTP 3 u 8)
1 cushion, saranet
(30 u 50)
9 flexible flat cable
(19 core) (CN1013)
0 CN1001 (10P)
2 CN1011 (2P)
4 CN1003
(2P)
C
C
qs three screws
(+PTPWH 2.6 u L (DIA8.0))
qf heat sink (M3)
qd sheet, thermal
Note 3:
When you install the connector, please install them correctly.
There is a possibility that this machine damages when not
correctly installing it.
Insert is shallow
Insert is straight
to the interior.
connector
Insert is incline
connector
connector
connector
connector connector
Note 2:
When installing the flexible flat cable, ensure that
the colored line is not slanted after insertion.
colored line
colored line
Insert is straight to the interior. Insert is incline
flexible flat cable flexible flat cable
connectorconnector
OK
NG
OK NG NG
4CH DAMP
board
Twist the wire
one turn
:LUHVHWWLQJ
rear side
rear side
Note 1:
Make sure the DC fan wire not touching
the 4CH DAMP board
4CH DAMP
board
cushion, saranet
(30X50)
SYSSET