1919
6-1. CIRCUIT BOARDS LOCATION
SECTION 6
DIAGRAMS
VIDEO SECTION
Frequency adjustment
1. Connect the frequency counter to check point TP508 (27MHz)
of the VIDEO board.
2. Adjust CT503 of the VIDEO board so that the frequency counter
read 27MHz ± 80Hz at STOP condition.
[ VIDEO BOARD ] – SIDE B –
Adjustment Location :
[ VIDEO BOARD ] – SIDE A –
frequency counter
VIDEO board
(27 MHz)
+
–
SL501
D502
SL502
CT503
TP508
SL503
TEST MODE
VIDEO
FREQUENCY
(27MHz)
(GND)
IC507
IC505
Adjustment Location :
[ BD BOARD ] — SIDE B —
TP
(VC)
TP
(RF)
TP
(TE)
TP
(IOP)
TP
(FE)
TP
(AGCCON)
TUNER UNIT
SURROUND AMP board
JACK board
VIDEO boar