— 12 —
KV-13FM13 / 13FM14
2-2. CONVERGENCE
Preparation:
• Perform FOCUS, V. LIN and V. SIZE adjustments.
• Set BRIGHTNESS control to minimum.
• Input dot pattern.
VERTICAL STATIC CONVERGENCE
1. Adjust V. STAT magnet to converge red, green and blue dots in the
center of the screen (Vertical movement).
B
G
R
Center dot
V.STAT magnet
RV1761 V.STAT
R G B
Tilt the V. STAT magnet and adjust static convergence to open or close
the V. STAT magnet.
2. When the V. STAT magnet is moved in the direction of arrow a and b,
red, green, and blue dots move as shown below:
a
b
b
B
G
R
a
b
B
G
R
a
BGR
RGB
b
R
G
B
b
b
a
R
G
B
(1)
(3)
(2)
HORIZONTAL STATIC CONVERGENCE
If the blue dot does not converge with the red and green dots, perform
the following:
1. Move BMC magnet (a) to correct insufÞ cient H. Static convergence.
2. Rotate BMC magnet (b) to correct insufÞ cient V. Static convergence.
3. After adjusting the BMC magnet, repeat Beam Landing Adjustment.
b
BMC magnet
BMC MAGNET
PURITY
V-STAT