Page14
Section5 Important: Operating Control
2. In COOLING cycle, if fluorescent display appears:
The temperature of cylinder achieves or lower than the lowest temperature setting.
The led of COOL and STANDBY will be sparked, compressor stop, beater motor
working.
Press RESET button, fluorescent display indicates STOP.
Lower viscosity setting in SET MENU item1 or contact the authorized service
technician to check lower the temperature of cylinder protection setting
Press the WASH button and observe the machine's performance.
If the beater motor is turning properly, press the RESET button.
Press COOL button to resume normal operation.
If no any button is pressed in 10 minutes, machine will enter STANDBY mode
automatically.
3. In COOLING cycle, if fluorescent display appears:
The electrical current of beater motor achieves or more than highest current setting,
the led of COOL will be sparked, machine stop.
Press RESET button, fluorescent display indicates STOP.
Lower viscosity setting in SET MENU item1 or contact the authorized service
technician to check highest current setting.
Press the WASH button and observe the machine's performance.
If the beater motor is turning properly, press the RESET button.
Press other button to resume normal operation.
4. In COOLING cycle, if fluorescent display appears:
The led of Mix Low will be blinking indicating that the mix hopper has a low supply of
mix and should be refilled as soon as possible.
Otherwise machine stop refrigeration of cylinder after Low mix delay. The time of Low
mix delay will be setting by service technician.
When you add enough mix, the led of Mix Low OFF, machine will enter COOL cycle
automatically.