EasyManua.ls Logo

Spaceman 6350 - OPERATING CONTROL: FREEZE (Page 15); ADD PRODUCT TO MACHINE; FREEZE PRODUCT

Spaceman 6350
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

1. Verify machine has been recently sanized (within
1 hour); if machine has not been recently
sanized, verify door hand-screws are ght, and
perform sanizing steps (Page 11).
2. Thoroughly mix and prepare at least 8 liters (2.11
gallons) of product according to manufacturer
instrucons; mix should be cool and smooth (free
of large chunks).
3. Place bucket or large container below draw valve.
4. Pour 2 liters (0.53 gallons) of product into hopper.
5. For machine with air pumps, use lter when add
mix. Do not ll product over small air inlet holes on
the boom of the air pump.
6. OPEN draw valve (Handle Down); sanizer will
start to ow out draw valve.
7. Once sanizer has been purged from the machine
and a steady stream of product is owing from the
spout, CLOSE draw valve (Handle Up).
8. Pour remaining product into hopper.
9. Raise the prime plug on the top of the dispensing
door unl ow is 100% product.
10. Push prime plug back down.
11. Wash air tube; install air tube in hopper (inlet hole
on side of air tube at boom).
12. For machine with air pumps:
Insert air tube into hopper but do not connect to
air pump
Press RESET, then press WASH to Prime
Ensure product is coming out of the large hole
near the top of the air pump. Press RESET
Rotate and insert air pump connector into air
pump; rotate connector to lock in place
13. Install hopper cover. Product is now ready to
freeze.
The mix-low lights illuminate  when a hopper is low on product mix and automacally
de-illuminate when machine is lled.
Instrucons assume product is added one hopper at a me. Repeat steps as needed.

 




1. Verify cylinder is full of mixed product and primed.
2. Press FREEZE buon.
3. The motor will begin to agitate the product, and the cooling system will begin to freeze the product.
4. Freezing product takes approximately 10 minutes.
5. When product reaches the set viscosity, it is ready to dispense (viscosity can be changed in the Sengs
menu (Page 16).


Never disconnect air pump (if present) with the machine running. If disconnecng air pump, rst press
RESET to stop operaons and open draw handles for 10 to 15 seconds to relieve pressure in cylinder.

Related product manuals