Chapter 4
Troubleshooting
Focus 30/35 Service Manual 4 - 34 P/N 79000035_SM, Version 1.5
Sensor specific messages Subsystem: FI_DARWIN_Knobs
General status combined from communication status 1 - 6 and sensor specific messages A - D:
Unknown
Ok
Not communicating...
Not initialized...
Not active...
Timeout warning
Failed warning
Sensor specific messages Subsystem: FI_Darwin_Knobs
5 Hz knob: no movement
Drive System: error message
warning 6
Drive error: 0x9c5a
(40026)not enough memory,
ReportingFI: 10, Info: Code:
0x9c5a P0: 0x0000 P1:
0x0000000b P2: 0x0000000
Knobs error:Error: 0x9c5a
(40026), ReportingFI: 10,
Info: Code: 0x9c5a P0:
0x0000 P1: 0x0000000b P2:
0x0000000
Check the Solenoid Hz
Exchange the Coarse drive
Hz
6 Drive system :Turn event
error warning 6 B D D1 C C1
FI: 10 Code: 0xf005
Message: 2|99|0|199994400|-
128327800|PositionHV faile
FI: 1 Code: 0x9c4e Message:
Drive system: Turn event
error warn. ( 6 B D
Check Coarse drive motor Hz
Exchange the Coarse drive
Hz
Value Value description Status Ok Counter Error Counter
All 3 knobs have to deliver signals, otherwise Run System diag. is not possible.
If one knob fails the
Run System diag. stops the aiming to target.
A SF Knob Ok 0 0- Ok status
1- Error message
B VA Knob Ok 0 0- Ok status
1- Error message
Item System Monitor messages
and message codes stored in
*.fsmx file
Error Log stored in
*.irep file
Recommendation