Chapter 5
Maintenance and Repair
Focus 30/35 Service Manual 5 - 92 P/N 79000035_SM, Version 1.5
3 Exchange Fine
drive V.
A. Unhook the spring
see Fig. 5-64 on
page 5-85 .
B. Select
Servo drive
test Hz/v from
Servo & angle test
in
Maintenance &
Service, see Fig. 6-
107 on page 6-134 .
C. Select
Fine drive
stops.
D. Select
V tick box.
E. Push the
In button.
F. Remove the three
screws with
washer.
G. Tilt the Fine drive
down and take it
out.
H. Unplug the motor
cable and pull it out
see Fig. 5-63 on
page 5-84
A;B.
I. Exchange Fine
drive V and mount
it back in reverse
order.
The fine drive motor
moves to the inner
position (right).
Precondition: The
motor is still
working otherwise
go to
Item 4 and
remove the Fine
drive and Coarse
drive together.
Item Performance Action Result Notes