EasyManua.ls Logo

Sperry Marine VisionMaster FT - Chart Installation; Chart Permissions; Chart Depths; Table 29: Chart Depth Threshold Values

Sperry Marine VisionMaster FT
674 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 1 VisionMaster Ship’s Manual
Chart Installation Technical Specification
1–38 65900011
7.21.7 Chart Installation
Chart Installation enables the loading of charts onto the system hard drive
from a chart installer utility. If the chart type supports network installation,
chart installation can be made from any node of the system.
Charts can be installed using a USB key. Where C-MAP charts are being
installed the key used will be pre-assigned with a unique user ID.
Where S-57 charts are being installed the key used will include information
such as the S-57 user permit.
For information on the chart installer see Chapter 6 ‘Chart Installation’.
7.21.8 Chart Permissions
Information on chart license and permit expiration can be viewed via a
secondary window. The Permissions window shows the following data:
•License
*
• Expiration Data
• Database
•Region
• Subscription Status
When a chart license or permit is about to expire a warning is generated. If
the C-MAP license has expired the system stops displaying the respective
charts.
7.21.9 Chart Depths
The following depth threshold values can be applied to charts:
Table 29: Chart depth threshold values
* Applicable to C-MAP charts only, replaced with cell permit if S-63 charts are being used.
Depth Default Min Max
Deep Contour 30 metres 7 metres 100 metres
Safety Depth 30 metres 2 metres 30 metres
Shallow Contour 2 metres 0 metres 10 metres