EasyManua.ls Logo

SPX CS4000 Mini - Address Switches; Backplane Fuses

SPX CS4000 Mini
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CS4000 Mini Controller with Ethernet
Page
3-12
T-38324-A 39-30-38324
Backplane Fuses
Fuse F4 is Littelfuse 239001, 5x20 mm, 1A, SLO BLO (SB) 250V (part number 13-10-61001). Fuse
F4 protects the DCM board inside the TCM.
Fuses F2 and F3 are Littelfuse 255.500, subminiature 0.5A (part number 13-10-4050). Fuse F2
protects the 24VDC to the tool, and Fuse F3 protects the 24VDC used with the discrete I/O circuits.
Address Switches
Each TCM has a unique serial address. The first six DIP switches on the address switch, SW-1, allow
you to set up the communication address, 1 to 32, for the TCM.
Switch 7 assigns the baud rate at which the TCM sends data to an attached computer. When switch 7
is in the OFF position, a baud rate of 9600 kbps is used. When switch 7 is in the ON position, a baud
rate of 57600 kbps is used. Switch 8 is used to set up the TCM for the “PFCS” Mode used by the
DaimlerChrysler Plant Floor Communication System.