In the event of a defect in the inlet solenoid valve, the error message
"MVIN!" is output. The error display will be reset as soon as the valve
is functioning properly again.
The error message "MVFL!" indicates a defect in the purge solenoid
valve. As soon as the defect has been rectified, the error display is
reset.
All OmniaTap xs
systems are equipped with an internal leakage
sensor. If water leaks inside the treatment unit in an uncontrolled
manner, the system issues the error message "Leakage!". In addition,
the system closes all valves and deactivates the pump. This error can
only be reset by restarting the system once the leak has been
eliminated.
If the system receives incorrect or no values from the level sensor, the
error "PSENS!" is displayed. To avoid overflowing the tank, the pumps
are stopped and the system stops operating. When the error is
resolved, the system will reboot and return to regular operation.
The Omnia
Tap
system is
equipped with a pressure inlet sensor, to
protect the system for running without water. If the sensor detects
no inlet pressure, the system stops running and the error “NO WT!
is shown.