43
_________________________________________________________________________________
OmniaTap xs
basic
; Version August 2023
Subject to technical changes
Inlet pressure is too low
Check the inlet pressure (feed
water pressure) and increase it
if necessary.
Leakage sensor responds /
error Leakage! Is displayed.
If the leak sensor comes into
contact with water, the system
inlet valve is closed to prevent
further water leakage.
Eliminate the leak and reset
the error by rebooting the
system.
The membrane of the pre
-
treatment cartridge is blocked
Install a new pre
-
treatment
cartridge
The pressure control valve or
the operating pressure is set
incorrectly
Please contact customer
service
Inlet
solenoid valve is defective
/ error MVIN! is displayed
Please contact customer
service
Pressure pump is defective or
works incorrectly
Please contact customer
service
The fill level sensor is defective
or is supplying incorrect data.
Error "PSENS!" is displayed.
Check the 5
-
pin plug
connection of the filling level
sensor on the back of the
treatment unit
No water can be withdrawn
Tank level too low
If the tank level is lower than
the minimum level (10%), no
water can be withdrawn. Wait
until the tank is sufficiently
(>15%) full
Withdrawal solenoid valve is
defective / error MVDIS! is
displayed
Please contact customer
service
There is air in the line from the
tank to the treatment unit
Prime the system by running
the draw for 5 minutes or until
water comes out. If necessary,
contact customer service