62
MENU 4 4. 
4. - AUTO CLOSE
time setting
4.-
0 3
Press and hold SET button for about 6 seconds to en-
ter main menu until “0.-” appears on the display then
release the button.
Press UP till “4.-” appears on the display.
Press SET enter into the AUTO CLOSE time and con
-
dition setting
Adjust the stalls from 0 1 to 99 , by buttons UP/
DOWN 5 seconds per stall AUTO CLOSE time calcu-
lation method is 5S*N, N=01—99.
The maximum AUTO CLOSE time is 495S, press the
SET button to store the required AUTO CLOSE time
setting, then the digital tube displays
4.1 which
means that it has entered the AUTO CLOSE con-
dition setting, Adjust by buttons UP/DOWN from
4.1 or 4.2 or 4.3, Select the corresponding
function, press the SET button to save and exit the
menu setting.
Note:
The AUTO CLOSE function is turned on, which me-
ans the door is controlled by the AUTO CLOSE but-
ton on the control box.
4. 1
Condition 4. 1 means: Only after the door is ope-
ned to the open limit position, the AUTO CLOSE
function is eective and starts timing.
4.2 Condition 4.2 means: After the door stops at
any position when opening, the AUTO CLOSE func-
tion is eective and starts timing.
4.3 Condition 4.3 means: No matter where the door is
open, as long as it is not at the close limit position, it
will automatically close.
Note:
a. If the infrared function is turned on, the AUTO CLOSE
timing will stop when the infrared is blocked by an ob-
stacle. After the obstacle removed, it will continue the
previous timing and automatically close the door.
b. When the door is about to close, the courtesy light
ashes for warning.
c. When the door is about to close, the warning light a-
shes to warn.
d. Note: The ashing time of the warning light follows
the courtesy light.
e. The AUTO CLOSE function can only be used when the
safety protection device is used correctly.
SETTINGS OF FUNCTION PARAMETERS IN MENU