EasyManua.ls Logo

Stoneridge SE5000 - Page 70

Stoneridge SE5000
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
68
Displays and data
Messages, warnings and malfunctions
Display Type Unit Description Action
1 Card 1
fault
Mal-
function
Card The driver card in slot 1 (“2” if
slot 2) is defective.
Eject card and check visually.
Clean with a soft damp cloth and
try again.
If the display still is shown, per-
form a self test ( page 83).
! 1 Card 1 time
overlap
Warning VU The time at which the inserted
driver card in slot 1 (“2” if
slot 2) was last withdrawn is
later than the UTC time in the
VU.
Check the UTC time of the VU
and adjust it if necessary
( page 57).
If the UTC time in the VU has de-
viated by more than 20 minutes,
take the tachograph to a tacho-
graph workshop for recalibration.
! 2 Card
auth.failure
Mal-
function
Card The VU security check for the
driver card in slot 2 (“1” if
slot 1) failed.
Eject card and check visually.
Clean with a soft damp cloth and
try again.
If the display still is shown, per-
form a self test ( page 83).
! Card
conflict
Warning Card Different card types have been
inserted in the slots at the
same time (e.g. workshop and
driver card).
Withdraw one of the cards.

Table of Contents