UPS(UninterruptedPowerSupply)
ItismandatorythattheprinterispoweredthroughaUPSunit,providedbythecustomer.Thisensures
that
thequalityofprintingisnotaffectedbypowerfluctuationsfromthemains.
theprintercomputerscanperformagracefulshutdown”intheeventofapowerfailure.
TheUPSspecificationsarelistedbelow.
Output
OutputPowerCapacity 2100W(minimum)
NominalOutputVoltage 230VAC
OutputFrequency(synctomains)
50/60Hz±3Hzuseradjustable±0.1
Topology Doubleconversiononline
Waveformtype Sinewave
ACoutputstaticvoltageregulation
±2%
OutputConnections IEC320C19
Batteries & Runtime
Bridgingtime Minimum60minutesat1500W
Interfaceport(s) RJ-45Serial,Smart-Slot
Network Management Cards
Remotemonitoringandcontrol ViatheLANnetwork
Computerinterface Commandlineability
1
Simultaneousremotemanagementaccess ViaTelnetorSSH
Abilitytoconfiguretimelagfrompowerfailure 10minutes
Reliability
MTBF 36months(minimum)
Table4UPSRequirements
2
____________________________________________________
1
CommandlineabilityisnecessaryfortheUPStobeabletoexecutescriptlocatedintheprintersoftware.
2
TheUPSrequirementsarebasedonthetimeitmighttaketocompletea"gracefulsystemshutdown."
Objet1000 Plus Electrical Requirements
15