21 STRATASYS / THE 3D PRINTING SOLUTIONS COMPANY
Inspect the printed samples.
Use the ruler to determine the number of clogged (missing’) nozzles
Enter the number of missing nozzles in the wizard.
Remove the sample, weigh it and enter the weight in the wizard.
The wizard uses the data collected to analyze the condition of the print heads and optimize them.
Head Optimization