Strautmann PP 1207 - 5.5 Faults in operational sequence

Strautmann PP 1207
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation and control
V 152 10 11 Rev.: END
5-13
5.5
Faults in operational sequence
Pressing shield does not move when in standard cycle
Causes:
Door or loading flap not closed
Door temporarily opened
Pressing shield is not in the upper end position
Rectification Close the press chamber door or the loading door.
Move the pressing shield up in manual mode. Restart the cycle
by pressing START.
Red "FAULT" signal lamp is flashing
Causes:
Loading door not closed
Rectification Close the loading door.
Set the solenoid – sensor distance on the loading door.
Pressing shield does not move up again when in automatic mode:
Causes:
Emergency Stop pressed
Press chamber/loading flap temporarily opened
Power failure
Bales finished message on (foil programme option)
Power supply interrupted
Rectification Release the Emergency Stop button. Move the pressing shield up
in manual mode.
Close the press chamber/loading door. Move the pressing shield
all the way up in manual mode.
See Bale finished (Chapter 5.4.3).
Move the pressing shield all the way up in manual mode once the
power is resumed.