EasyManua.ls Logo

Strobl Strocomp 433 - 7 Faults, Cause and Remedy; Machine, General

Strobl Strocomp 433
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Faults, Cause and Remedy
7 2 06_0049_0802GB
The following section provides a description of possible causes of
f
a
ults and their remedies.
Danger
Make sure the mains power supply is suitable!
Otherwise the machine may be damaged.
Note
Consult the relevant service department at Maschinenbau Rudolf
GmbH if you cannot rectify the fault by yourself.
Machine does not start when switched on.
Cause Remedy
No power present. Check the electrical connection to the mains power supply.
Machine is connected to an
unsuitable power supply.
Connect the machine to the correct mains power supply.
Refer also to chapter: ”General Technical Description” -- section:
”Technical data”.
The machine may be damaged if connected to an unsuitable
mains power supply.
Wire break in the supply cable. Replace the supply cable.
The supply cable is too long. Use the supply cable specified.
Refer also to chapter: ”General Technical Description” -- section:
”Technical data”.
The electric supply cable is
wound up, e.g. on a cable
drum.
Wind up the electric supply cable.
The maximum backup fuse on
the machine is too small.
Use the correct backup fuse.
Refer also to chapter: ”General Technical Description” -- section:
”Technical data”.
Continued next page