Maintenance
8 — 3
07_0075_0802GB
Reference
other intervals
every 2 years
annually
every 1000 h
every 500 h
every 400 h
every 300 h
every 150 h
every 100 h
every 50 h
once after 50 h
Action
daily
General machine
Electrical cabling: visual
inspection, have repaired
if necessary
n
Air line: visual inspection
for suitability, wear and
damage, replace if
necessary
n
Draining condensate
water
Z
MC 43--039
Have a qualified service
expert check for defects
n
Service
Operational safety check
(German Accident Pre-
vention Regulation)
n
Service
Safety equipment
Check the safety valve,
have replaced if
necessary
n
In ac-
cord-
ance
with op-
erational
safety
regula-
tions
By an officially
certified test centre
Compressor (depending on the model)
Check the compressor oil
level, top up if necessary
n
MC 43--040
Compressor oil
⇔ ⇔
⇔
once
after
100 h
MC 43--041
Clean air filter, replace if
necessary
Z
⇔
as
required
MC 43--042