Maintenance Chart
43--042
Page 2 of 2
8 14 WK43_042_0802GB
The following steps describe how to clean and change the air filter:
" R
emove the air filter.
" Remove the filter cover.
" Pull the filter insert carefully from the filter housing. Avoid
disturbing dust where possible.
" Clean the inside of the filter housing and cover with a clean
cloth. Pay particular attention to cleaning the sealing surfaces.
" Inspect the filter element.
Note
Heavily soiled or damaged filter elements should be replaced with
new elements and discarded.
" Clean the filter element by blasting dry air from the inside to the
outside.
Note
When blowing out, the air pressure must not exceed 5 bar. The filter
element must not be damaged. A suitable distance must be
maintained between hose nozzle and filter element.
" Place the cleaned or new filter element in the filter housing.
" Fit the filter lid again. Ensure that it is correctly seated.
" Install the air filter again. Ensure that it is correctly seated.
" Clean or replace the second air filter in the same way.