EasyManua.ls Logo

Studer OnAir 3000 - TEST State

Studer OnAir 3000
352 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STUDER Professional Audio GmbH Compact SCore Technical Info
13.Feb.06 11/22
3.1.4 TEST State
The DSP Card can be put in an endless SDRAM memory test by setting Switch 1 to ON. This State is indicated
on the LED bar when the top two LEDs are lit.
A pre-defined sequence of memory-tests are performed and indicated on the first 8 LEDs (from bottom up)
similar to the transition from IDLE to PROCESSING. The last of the 8 tests does not end and toggles the
according LED periodically if no error occurred.
Remember that this test will prevent the Card from going into any other State (no booting possible).
PROCESSING
IDLE
endless Test in progress
Test 7 successfully passed
Test 6 successfully passed
Test 5 successfully passed
Test 4 successfully passed
Test 3 successfully passed
Test 2 successfully passed
Test 1 successfully passed
If the top two LEDs should go on during normal operation the resulting LED pattern is for R&D internal
meaning to Studer Professional Audio GmbH.

Table of Contents

Other manuals for Studer OnAir 3000

Related product manuals