4-10 Sun StorEdge 3000 Family FRU Installation Guide May 2004
4.5 FC Battery Status and In-Service Date
Procedures
The CLI and SSCS programs offer the following features for FC battery modules:
Setting the In-Service Date
Monitoring the FC battery status
4.5.1 Viewing Status and Setting the In-Service Date
with the CLI
This command sets the in-service date for battery FRU replacements and displays
the status of the battery modules.
For battery FRU replacements, the battery in-service-date must be set manually
with the show battery-status command after the battery FRU module is
installed. The show battery-status command will prompt you to set the in-
service date to the system clock date. Run this command immediately to ensure
the battery status is accurate when you run the show battery-status
command in the future.
For redundant controllers, status for both batteries is shown. Status values
include: Expired, Warning, or Good. A status of Warning indicates that the battery
will expire within 21 days.
Note If the battery type is an early board module, then battery expiration
monitoring is not supported. In this case, a message displays that says, “battery
board type is not supported.”

Table of Contents

Other manuals for Sun Microsystems StorEdge 3510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems StorEdge 3510 and is the answer not in the manual?

Sun Microsystems StorEdge 3510 Specifications

General IconGeneral
BrandSun Microsystems
ModelStorEdge 3510
CategoryStorage
LanguageEnglish

Related product manuals